828 []:
Pilot wont stay lit
|
|
ACCENT 20 []:
BLOWER DIAGNOSIS
|
FLAME LIFTING (B/Vent model)
|
UNIT IS CARBONNING
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
MAIN BURNER WON'T LIGHT
|
VALVE CHECK (820 Nova Sit Valve)
|
PILOT WON'T LIGHT (Spill Switch)
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Gas Testing)
|
PILOT WON'T LIGHT (Ignition Testing)
|
|
|
ACCENT 25 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE .(as follows) pilot is on for at least 3 mins
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
PILOT WON'T LIGHT (Spill Switch)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
ASCOT []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE .(as follows) pilot is on for at least 3 mins
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
PILOT WON'T LIGHT (Spill Switch)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
|
BBQ 3500 []:
Will not light
|
Not Defined
|
|
BBQ 4500 []:
Will not light
|
Flame Orange
|
|
|
BEDFORD []:
SEE WESTPORT
|
|
DV36 []:
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
BLOWER DIAGNOSIS
|
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(t/couple/t/pile)
|
PILOT WILL NOT LIGHT(gas testing)
|
PILOT WILL NOT IGNITE (ignition testing)
|
|
|
DV42 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
BLOWER DIAGNOSIS
|
|
DV50 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
BLOWER DIAGNOSIS
|
|
|
EF2 []:
UNIT SHUTS DOWN (after exhaust temp has been change)
|
STOVE WILL NOT START
|
STOVE WILL NOT LIGHT
|
STOVE WILL NOT OPERATE IN (auto mode)
|
THE EXHAUST BLOWER WILL NOT OPERATE
|
THE CONVECTION BLOWER WILL NOT FUNCTION NORMALLY
|
AUGER MOTOR WILL NOT FUNCTION NORMALLY
|
DIAL-A-FIRE HAS NO EFFECT ON "FIRE"
|
STOVE WILL NOT SHUT OFF
|
STOVE KEEPS GOING OUT
|
IGNITOR WILL NOT FUNTION NORMALLY
|
|
EF3 []:
IF REPLACING THE START UP TIMER
|
STOVE WILL NOT START
|
STOVE WILL NOT OPERATE WHEN HOT
|
EXHAUST BLOWER WILL NOT FUNCTION
|
CONVECTION BLOWER WILL NOT FUNCTION NORMALLY
|
IGNITOR WILL NOT LIGHT
|
AUGER MOTOR DOES NOT FUNCTION NORMALLY
|
DIAL-A-FIRE HAS NO EFFECT
|
STOVE WILL NOT SHUT OFF
|
STOVE KEEPS GOING OUT
|
|
|
EF4 []:
IF REPLACING THE START UP TIMER
|
STOVE WILL NOT START
|
STOVE WILL NOT OPERATE WHEN HOT
|
EXHAUST MOTOR WILL NOT FUNCTION NORMALLY
|
CONVECTION BLOWER WILL NOT FUNCTION NORMALLY
|
IGNITOR WON'T LIGHT
|
AUGER MOTOR WILL NOT FUNCTION NORMALLY
|
DIAL-A-FIRE HAS NO EFFECT
|
STOVE WILL NOT SHUT DOWN
|
STOVE KEEPS GOING OUT
|
|
EF5 []:
THEMOSTAT INTERPHASE DOES NOT WORK CORRECTLY
|
STOVE KEEPS GOING OUT
|
STOVE WILL NOT SHUT OFF
|
DIAL-A-FIRE HAS NO EFFECT
|
AUGER MOTOR DOES NOT FUNCTION NORMALLY
|
IGNITOR WILL NOT LIGHT
|
CONVECTION BLOWER WILL NOT FUNCTION NORMALLY
|
STOVE WILL NOT OPERATE WHEN HOT
|
EXHAUST BLOWER WILL NOT FUNCTION NORMALLY
|
STOVE WILL NOT START
|
|
|
EG20 []:
SEE ACCENT 20
|
|
EG22 []:
If not , check fan controller
|
Bypass fan controller, heat up sensor if fan works replace controller
|
If fan runs, replace sensor
|
If okay, bypass fan sensor with jumper wire
|
If damaged replace it
|
If fan does not operate replace it
|
If okay, Check fan sensor for visible damage
|
Use a power cord direct to blower, plugged into a wall outlet
|
Check fan for visible damage
|
Make sure the wiring is correct as per manual
|
Make sure fan control knob is in the on position
|
Make sure fan is plugged in
|
BLOWER DIAGNOSIS
|
|
|
EG25 []:
SEE ACCENT 25
|
|
EG28 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
|
EG31 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
EG40 []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
|
HAVEN []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
BLOWER DIAGNOSIS
|
|
MERIDIAN []:
Check vacuum hose for cracks, pinched & should be on bottom port of vac. Switch
|
If okay
|
Check fuse # F2
|
If motor works
|
If auger does not turn, replace it
|
Apply direct power to motor
|
Disconnect auger motor from wire harness
|
Check all connections to auger, circuit board, vacuum sensor, 200 hi limit
|
Unplug unit and remove right & left side access panels
|
Make sure auger light (Green) is flashing
|
Make sure #1 red light is on
|
Make sure exhaust blower is operating
|
AUGER MOTOR WILL NOT FUNCTION
|
HEAT LEVEL BUTTON HAS NO EFFECT
|
IGNITOR-PELLETS WON'T LIGHT
|
CONVECTION FAN WON'T FUNCTION NORMALLY
|
LIGHT #3 FLASHING
|
STOVE WILL NOT START
|
STOVE WILL NOT OPERATE
|
LIGHT #2 FLASHING
|
|
|
RETREAT []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
BLOWER DIAGNOSIS
|
|
SIENNA []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
|
SOLUS []:
SEE EF4
|
|
VISTAFLAME []:
SEE EF3
|
|
|
WESTPORT []:
TO TEST THERMOCOUPLE ( 820 Nova Sit Valve as follows)
|
TO TEST THERMOPILE (as follows) prior to test pilot on for at least 3 minutes
|
PILOT WON'T STAY LIT(T/couple/T/pile)
|
PILOT WON'T LIGHT (Ignition Testing)
|
PILOT WON'T LIGHT (Gas Testing)
|
VALVE CHECK (820 Nova Sit Valve)
|
MAIN BURNER WON'T LIGHT
|
MAIN BURNER LIGHTS IN THE PILOT POSITION
|
UNIT IS CARBONNING
|
FLAME LIFTING (D/Vent model)
|
FLAME LIFTING (B/Vent model)
|
BLOWER DIAGNOSIS
|
|
WINDSOR []:
If the unit does not start
|
Light # 3 on Heat Output bar flashing/orange wires on vacuum
|
Light # 2 on Heat output bar flashing/orange wires on vacuum
|
Light # 3 on Heat Output bar flashing/grey wires on vacuum
|
Light # 2 on Heat output bar flashing/grey wires on vacuum
|
HI / LOW mode w/ thermostat or wall switch:
|
ON/OFF mode w/ thermostat or wall switch:
|
MANUAL mode, Factory setting w/no thermostat or wall switch
|
The stove keeps going out
|
Circuit Board Operation and Troubleshooting
|
Control settings (Heat Level) has no effect on the fire
|
The auger motor will not function normally
|
The convection blower will not function normally
|
Igniter does not function
|
The exhaust motor will not function normally
|
The stove will not operate when hot
|
The stove will not start
|